Sensitive quantification of the HIV-1 reservoir in gut-associated lymphoid tissue.
Ver todas las publicaciones
Sensitive quantification of the HIV-1 reservoir in gut-associated lymphoid tissue.
Background: The implementation of successful strategies to achieve an HIV cure has become a priority in HIV research. However, the current location and size of HIV reservoirs is still unknown since there are limited tools to evaluate HIV latency in viral sanctuaries such as gut-associated lymphoid tissue (GALT). As reported in the so called "Boston Patients", despite undetectable levels of proviral HIV-1 DNA in blood and GALT, viral rebound happens in just few months after ART interruption. This fact might imply that current methods are not sensitive enough to detect residual reservoirs. Showing that, it is imperative to improve the detection and quantification of HIV-1 reservoir in tissue samples. Herein, we propose a novel non-enzymatic protocol for purification of Lamina Propria Leukocytes (LPL) from gut biopsies combined to viral HIV DNA (vDNA) quantification by droplet digital PCR (ddPCR) to improve the sensitivity and accuracy of viral reservoir measurements (LPL-vDNA assay).
Methods: Endoscopic ileum biopsies were sampled from 12 HIV-1-infected cART-suppressed subjects. We performed a DTT/EDTA-based treatment for epithelial layer removal followed by non-enzymatic disruption of the tissue to obtain lamina propria cell suspension (LP). CD45+ cells were subsequently purified by flow sorting and vDNA was determined by ddPCR.
Results: vDNA quantification levels were significantly higher in purified LPLs (CD45+) than in bulk LPs (p0.01). The levels of vDNA were higher in ileum samples than in concurrent PBMC from the same individuals (p = 0.002). As a result of the increased sensitivity of this purification method, the Poisson 95% confidence intervals of the vDNA quantification data from LPLs were narrower than that from bulk LPs. Of note, vDNA was unambiguously quantified above the detection limit in 100% of LPL samples, while only in 58% of bulk LPs.
Conclusion: vDNA quantification levels were significantly higher in purified LPLs (CD45+) than in bulk LPs (p0.01). The levels of vDNA were higher in ileum samples than in concurrent PBMC from the same individuals (p = 0.002). As a result of the increased sensitivity of this purification method, the Poisson 95% confidence intervals of the vDNA quantification data from LPLs were narrower than that from bulk LPs. Of note, vDNA was unambiguously quantified above the detection limit in 100% of LPL samples, while only in 58% of bulk LPs.